Planning the installation
Possible installation variants
Note:
Detailed installation instructions can be found in the section “Installation and startup.”
Variant 1: flush-mounted in a dropped/coffered ceiling

Ceiling microphone installation kit: TCC M Plus F-W (white) or TCC M Plus F-B (black)
Variant 2: installed flush with the Ceiling Tile panel in a dropped/coffered ceiling

Ceiling microphone installation kit: TCC M CTFP-W or TCC M CT-W 2FT
Variant 3: mounted directly below the ceiling

Ceiling microphone housing set: TCC M Plus S-W (white) or TCC M Plus S-W (black)
Variant 4: suspended from the ceiling

Accessories required:
VESA mount

Installation information:
Adapting the installation height
Note:
When installing the TeamConnect Ceiling M Plus, observe the following minimum and maximum distances.
The recommended distance between the speaker and the TeamConnect Ceiling M Plus should be a maximum of 3 to 3.5 m.
The minimum distance between the TeamConnect Ceiling M Plus and the floor should be at least 2.50 m.
Note:
If installation variants 1 or 2 would result in a distance greater than the recommended maximum due to the room height, we recommend installation variant 3.
Recommended distances for variants 1 and 2:

Distance A: max. 3 - 3.5 m
Distance B: min. 2.5 m
Recommended distances for variant 3:

Distance A: max. 3 - 3.5 m
Distance B: max. 5 m
Distance C: min. 2.5 m