Variant 1: installed flush in a dropped/coffered ceiling

The TeamConnect Ceiling M Plus can easily be installed flush in dropped or closed ceilings.

For this, a corresponding ceiling installation kit is supplied with the product variant TCC M Plus F. Make sure not to install the TeamConnect Ceiling M Plus directly next to lights or other electrical devices in the ceiling.

Attaching the ceiling flush mount kit
  1. Remove a tile from the ceiling.
  2. Trace the circumference using the drilling template supplied and saw the hole.
  3. Using a suitable anchor, insert an eye bolt into the ceiling to attach the installation rope.
  4. Reinsert the ceiling tile.

  5. Assemble the longitudinal sections of the ceiling flush mount kit by hooking them into each other at right angles and then straightening them out until they snap into place.

  6. Place the longitudinal sections over the crossbeams in the coffered ceiling.
  7. With the C-ring closed or slightly open, guide it through the hole and unfold it.
  8. Slide the tabs on the C-ring onto the longitudinal sections on both sides.
  9. Attach the ceiling flush mount kit by inserting the supplied screws through the slots on both sides.

Securing and connecting the microphone
  1. Install the suspension cable as shown and attach it to the eye bolt and the microphone.
  2. If using, mount the TCC M SK ceiling suspension kit (see Variant 4: suspended from the ceiling).
  3. Insert the cables you need.
  4. If required, you can attach a cover plate (included with delivery) and pipe clamps (not included with delivery).
    Note:
    Recommended cabling

    Observe the following when connecting and running the cables:

    • Always run the cables carefully and in a loop shape inside the installation recess.
    • Make sure not to kink the cables to avoid breaking them or damaging the plugs.
  5. Lift the microphone toward the ceiling, pull the rope tight and cut off any superfluous length of rope.

Securing the microphone and attaching the front panel
  1. Hold the microphone in the ceiling flush mount frame with one hand and use the other hand to screw the three clamps until tight.
  2. Look through the inspection holes to check that the clamps are properly tightened and the microphone is firmly seated in the frame.

  3. Insert the guy rope on the front panel into the corresponding recess in the microphone as shown and secure it with the supplied screw.

  4. Insert the two pins of the retaining plate into the corresponding holes in the microphone (marked in red). The front panel is now held magnetically.