Variant 1: installed flush in a dropped/coffered ceiling
The TeamConnect Ceiling M Plus can easily be installed flush in dropped or closed ceilings.
For this, a corresponding ceiling installation kit is supplied with the product variant TCC M Plus F. Make sure not to install the TeamConnect Ceiling M Plus directly next to lights or other electrical devices in the ceiling.
Attention
Danger of property damage if the product should fall
If mounted incorrectly, the product may fall.
When mounting in the ceiling, always additionally secure the TeamConnect Ceiling Medium Plus against falling, e.g. with the supplied ceiling suspension set TCC M SK (see Variant 4: suspended from the ceiling) and additionally with the supplied suspension cable, which is attached to a ceiling hook and the top of the microphone.
Attaching the ceiling flush mount kit
Remove a tile from the ceiling.
Trace the circumference using the drilling template supplied and saw the hole.
Using a suitable anchor, insert an eye bolt into the ceiling to attach the installation rope.
Reinsert the ceiling tile.
Assemble the longitudinal sections of the ceiling flush mount kit by hooking them into each other at right angles and then straightening them out until they snap into place.
Place the longitudinal sections over the crossbeams in the coffered ceiling.
With the C-ring closed or slightly open, guide it through the hole and unfold it.
Slide the tabs on the C-ring onto the longitudinal sections on both sides.
Attach the ceiling flush mount kit by inserting the supplied screws through the slots on both sides.
Securing and connecting the microphone
Install the suspension cable as shown and attach it to the eye bolt and the microphone.