Finding minimum and maximum values

Searching for the minimum field strength – “RF Level Recorder” only
The “RF Level Recorder” allows you to search for measured field strength values that are below the squelch threshold. The search always refers to the measured values of both antennas.
  1. Click on “Search Low RF”.
    The lowest measured field strength value that is below the squelch threshold is displayed. A marker appears at this point.
  2. Click again on “Search Low RF” to search for the next higher measured value.
Searching for the maximum field strength – “RF Spectrum Analyzer” only
The “RF Spectrum Analyzer” allows you to search for field strength peaks.
  1. Click on “Search RF Peak”.
    The highest measured field strength value is displayed. A marker appears at this point.
  2. Click again on “Search RF Peak” to search for the next lower measured value.