Split Mode
In this mode, the Sennheiser control software and the Dante Controller are located in different networks and both have different IP and MAC addresses. All data packages are untagged.
The Split Mode is available for the TC Bar M only.
This mode is generally used if you receive two different IP and MAC addresses (one for Dante® and one for Control). In this way, you want to operate the Dante® network and the control network independently of each other and use a separate switch for each network.
The Ethernet connections can be used to address the TC Bar both via the control software
and via the Dante Controller as follows:
- Ethernet port I: Control only
- Ethernet port II: Dante® only
TC Bar M
- The first Ethernet connection provides an IP address for the control software network only.
- The second Ethernet connection provides an IP address for the Dante®
network only. NOTICEThere is a potential risk of creating loops (see Danger of Network Loop).
- Make sure you always connect the TC Bar M to two different networks that do not run via a common switch.