Power saving mode

In power saving mode, the transmitters are charged only once. The charger also does not provide any trickle charge.

To activate power saving mode:
In power saving mode, the CHG 70N-C cannot be controlled over the network.
  1. Remove all transmitters and/or rechargeable batteries from the charging slots.
  2. Hold the Reset button for 4 seconds.
    The charging slot LEDs light up purple.
  3. Insert the rechargeable battery/transmitter for charging.
    The rechargeable battery will begin charging. The charging slot LED turns green once it reaches full charge.
To deactivate power saving mode:
  1. Disconnect the charger from the power supply system.
  2. Then reconnect it to the power supply system.
    The charger will start up in the configuration that was set before you activated power saving mode.