Installing the AC 3200-II in a rack
| CAUTION | |
|---|---|
To mount the AC 3200-II into a 19" rack:
- Slide the AC 3200-II into the 19" rack.
- Secure the rack mount “ears” to the rack using four screws (to be ordered separately).
| CAUTION | |
|---|---|
Rack mounting poses risks!
When installing the device in a closed or multi-rack assembly, please consider that, during operation, the ambient Temperature, the mechanical loading and the electrical potentials will be different from those of devices which are not mounted into a rack.
Make sure that the ambient Temperature within the rack does not exceed the permissible Temperature limit specified in the specifications. See Specifications.
Ensure sufficient ventilation; if necessary, provide additional ventilation.
Make sure that the mechanical loading of the rack is even.
When connecting to the power supply system, observe the information indicated on the type plate. Avoid circuit overloading. If necessary, provide overcurrent protection.
When rack mounting, please note that intrinsically harmless leakage currents of the individual power supply units may accumulate, thereby exceeding the allowable limit value. As a remedy, ground the rack via an additional ground connection.
| |