Variant 3: suspended from the ceiling

For suspended mounting, you need the SL CM SK ceiling suspension set.

Screws and anchors for mounting the product to the ceiling are not included with delivery. Use screws and anchors that are appropriate for the particular characteristics of your ceiling.

TeamConnect Ceiling 2 von der Decke abhängend montieren

Preparing the ceiling fastener
  1. Unscrew part A of the ceiling fastener from part B.
  2. Thread the steel cable C into part B so that the ball on the steel cable is in part B.
  3. Repeat these steps for the other three fasteners.
    TeamConnect Ceiling 2 Montageschritt

Mounting the ceiling fastener
  1. Attach part A of the ceiling fastener to the ceiling using a suitable anchor and screw.
  2. Use the included drilling template to align the drill holes.
    TeamConnect Ceiling 2 Bohrschablone nutzen

  3. Then screw part B of the ceiling fastener into part A.
    TeamConnect Ceiling 2 A und B zusammenfügen

  4. Repeat these steps for the other three fasteners.
Mounting the product fastener
  1. As shown in the figure, screw the product fastener D into the threaded mounting hole on the top of the TeamConnect Ceiling 2.
  2. Set the steel cable C to the desired length by using your finger to press the cable guide into the product fastener D and sliding the steel cable as needed.
  3. Cut the excess steel cable using suitable pliers.
  4. Repeat these steps for the other three fasteners.
    TeamConnect Ceiling 2 Höhe einstellen

The TeamConnect Ceiling 2 is now suspended from the ceiling.