MEB 104-L

Specifications

Pick-up pattern
  • Cardioid
Frequency response
  • 40 – 20,000 Hz
Acoustic operating principle
  • Boundary microphone
Output impedance at 1 kHz
  • 200 Ω
Sensitivity
  • 14 mV/Pa
Maximum sound pressure level
  • 125 dB at 1 kHz < 3 %
Equivalent noise level
  • 28 dB(A)
  • 38 dB(CCIR)
Dynamic range
  • 97 dB(A)
Power supply
  • 24 V – 48 V phantom power (P 24 – P 48)
Current consumption
  • 6 mA (microphone/luminous ring each 3 mA)
Connector
  • XLR-5M
TTL level for LED activation
  • High > 2.4 V
  • Low < 0.4 V
Weight
  • 60 g
Dimensions
  • Installation height: approx. 19 mm
  • Total height: approx. 90 mm
  • Microphone head diameter: approx. 29 mm
  • Thread diameter: approx. 20 mm
  • Thread: M20 x 1.5
  • Rubber washer diameter: approx. 23 mm
Temperature
  • Operation: 0 °C to +40 °C (32 °F to 104 °F)
  • Storage: -25 °C to +70 °C (-13 °F to 158 °F)

Connector assignment



1 GND
2 Audio +
3 Audio -
4 LED green (control signal)
5 LED red (standard)

Polar diagram



Frequency response